- LDG-A1B50-C3D1E2-F2G1H1-I1J1
- Model: LDG-A1B50-C3D1E2-F2G1H1-I1J1
- Hãng: Supmea
Lưu lượng kế điện từ
Size: DN50
Lining material: PTFE
Power supply: 24VDC
Output: Pulse, 4-20mA, RS485-
Bảng giá sản phẩm
Số lượng Giá bán (VNĐ) 1+ Liên hệ 5+ Liên hệ 10+ Liên hệ 20+ Liên hệ Chưa bao gồm VAT
Thông tin đặt hàng4-6 tuần
Tối thiểu: 1Đặt hàng
- Mô tả chi tiết
- Thông số kỹ thuật
- Bình luận
Đồng Hồ Đo Lưu Lượng Điện Từ
Model LDG-A1B50-C3D1E2-F2G1H1-I1J1
Size: DN50
Lining material: PTFE
Power supply: 24VDC
Output: Pulse, 4-20mA, RS485
Connection: Flange DN50, PN16
Display: Graphical display
Accuracy: 0.5%
UP-LDG Carbon steel body electromagnetic flow meter
SUP-LDG electromagnetic flow meter is applicable for all conductive liquids. Typical applications are monitoring accurate measurements in liquid, metering and custody transfer. Can display both instantaneous and cumulative flow, and supports analog output, communication output and relay control functions.
Features
- Pipe diameter: DN15~DN1000
- Accuracy: ±0.5%(Flow speed > 1m/s)
- Reliability: 0.15%
- Electric conductivity: Water: Min. 20μS/cm; Other liquid: Min. 5μS/cm
- Turndown ratio: 1:100
- Power supply: 100-240VAC,50/60Hz; 22-26VDC
-
Specification
Product: Electromagnetic flowmeter
Model: SUP-LDG
Diameter nominal: DN15~DN1000
Nominal pressure: DN6 - DN80, PN<4.0MPa; DN100 - DN150, PN<1.6MPa; DN200 – DN1000, PN<1.0MPa; DN1200 – DN2000, PN<0.6MPa
Accuracy: ±0.5%,±2mm/s(flowrate<1m/s)
Repetitiveness: 0.15%
Liner material: PFA, F46, Neoprene, PTFE, FEP
Electrode material: Stainless steel SUS316L, Hastelloy C, Titanium, Tantalum, Platinum-iridium
Medium temperature: Integral type: -10℃~80℃; Split type: -25℃~180℃
Power supply: 100-240VAC,50/60Hz / 22-26VDC
Electrical conductivity: IP65, IP68(optional)
Product standard: JB/T 9248-2015
-
Measuring principle
Mag meter works based on Faraday's law, when the liquid goes through the pipe at the flow rate of v with a diameter D, within which a magnetic flux density of B is created by an exciting coil, the following electromotive E is generated in proportion to flow speed v:
E=K×B×V×D
Where:
E-Induced electromotive force
K-Meter constant
B-Magnetic induction density
V-Average flow speed in cross-section of measuring tube
D-Inner diameter of measuring tube
-
Introduction
Noted: the product strictly prohibited to be used in explosion-proof occasions.
-