- Cảm biến lực GS-1A
- Model: GICAM GS-1A
- Hãng: Gicam
Cảm Biến Lực Trục Quay
Dãi đo: 10, 15, 20, 25, 30, 50, 75, 100, 150.
Ngõ ra: 2 mV/V
Nguồn cấp: Vcc 15 Max
-
Bảng giá sản phẩm
Số lượng Giá bán (VNĐ) 1+ Liên hệ 5+ Liên hệ 10+ Liên hệ 20+ Liên hệ Chưa bao gồm VAT
Thông tin đặt hàng4-6 tuần
Tối thiểu: 1Đặt hàng
- Mô tả chi tiết
- Thông số kỹ thuật
- Bình luận
Technical Specifications
Material | Stainless steel |
Nominal load | 10, 15, 20, 25, 30, 50, 75, 100, 150, 250, 300, 500, 750 kg |
Limit load | 150 % F.S. |
Breaking load | 300 % F.S. |
Supply voltage | Vcc 15 Max |
Output | 2 mV/V |
Output tollerance | 0,1 % F.S. |
Zero tollerance | 1 % F.S. |
Linearity | 0,03 % F.S. |
Hysteresis | 0,03 % F.S. |
Reapeatability | 0,03 % F.S. |
Input resistance | 380-386 ohm |
Output resistance | 350-353 ohm |
Insulation resistance | >= 2000 MOhm |
Creep (30 Minutes) | 0,03 % F.S. |
Thermal compensation | -10 / +40°C (14 / +104°F) |
Operating temperature | -20 / +70°C (-4° / +158°F) |
Temperature deviation zero | 0,003 % F.S. / °C |
Temperature deviation full scale | 0,002 % F.S. / °C |
Protection class | IP 67 |
Standard cable length | 5 m – 6 x 0,30 (shield not connected to the load cell body) |
Download PDF
Connections
Type | SHIELDED CABLE 6C R6 PVC 6X0,30 |
Length | 5 m (body lead cell not connected shield) |
Red | + IN |
Black | - IN |
Yellow | + REF |
Blue | - REF |
Green | + OUT |
White | - OUT |
MOUNTING OF THE LOAD CELL
General precautions to be followed in the installation and assembly of load cells:
- Follow the direction of application of force on the load cell
- Do not exceed the limits of the temperature as indicated in the data sheet
- Do not remove labels from the load cell
- Adequately protect the cables with sleeves or channels
- Carry out on each load cell a ground connection with suitable cable, shunt on mounting accessories
- Do not carry out any welding on the mechanical structure after mounting the load cell
- Avoid or reduce to a minimum level any mechanical constraints between the rigid structure and the weighing structure to avoid error in weighing and return to zero
- In case of vibration or dynamic loads product the load cells with puffers / shock absorbers